Dynamic temperature control system is a hermetic refrigerated heating circulator which is designed for fast heat-up and cool-down times in external applications.
Circulatory devices capable of providing cold and heat sources, with a wide working range, are used in pharmaceutical, chemical, biological, and other industries to provide heat and cold sources for reaction tanks, troughs, and so on, as well as for heating and cooling in other equipment.
DOVMXtech Dynamic Temperature Control System:
Selling point
-
For many years of production technology and experience, The equipment is scientific in design, safe and reliable, stable in operation, simple in operation, high quality and reasonable price;
-
Imported brand compressor with guaranteed power used to increase the service life. The service life is up to five years;
- Wide working temperature ranges using one bath fluid: -20℃~200℃;
- Refrigeration system, heating system and pre-cooling system can work independently or work together continuously;
- It is available with air cooling and water cooling;
- Multi safety protections: Over temperature cut-off, electrical leakage prodtection, over-current protection etc.;
- Designed with bath fluid monitoring window, avoid shortage of liquid;
- Rapid heat-up or cool-down;
- Dovmxtech Dynamic Temperature Control System are exported to many countries, such as the United States, Canada, Colombia, Italy, the Netherlands, Poland, Australia and Thailand;
-
DOVMXtech brand is well-known worldwide;
-
We are a well-known OEM supplier of laboratory equipment in the United States and Canada;
-
Equipment can be customized according to customer requirements;
-
We can provide door-to-door transportation services, worry-free delivery, including customs clearance;
-
Recruit distributor partners globally. We have a very mature pricing system for distributors, fully guaranteeing the interests of distributors.
Application characteristics:
A circulation device capable of providing a heat source or a cold source. It has a wide range of work and can be used in pharmaceutical, chemical, biological and other industries to provide heat and cold sources for reactors and tanks.
● wide temperature control range: - 20 ℃ ~ 200 ℃.
● precooling system, refrigeration system and heating system can be used in combination.
● rapid heating or cooling.
● large cooling rate, which can be forced to cool quickly.
● totally closed circulation system, heat conducting fluid is not easy to volatilize and oxidize at high temperature; It is not easy to be affected by environmental conditions at low temperature and can prolong the service life of the heat transfer fluid.
● fully brazed plate heat exchanger is adopted for refrigeration heat exchanger, which occupies small space and has high heat exchange efficiency.
● liquid level display function to monitor liquid level in real time to avoid lack of heat carrying fluid.
● over temperature protection, leakage protection, overcurrent protection and other protection functions to fully ensure the safety of users and equipment.
● according to the user's requirements, air cooling and water cooling can be provided.
● divided into 3 systems: refrigeration system, heating system, pre cooling system, the three systems can be used continuously or separately.
● rapid heating and cooling to continuously raise and fall temperatures.
● wide temperature control range, no need to change conductive medium throughout, less conductive medium consumed.
● fully closed circulatory system, thermally conductive fluid is not volatile and oxidized at high temperature, and moisture in air is not easily inhaled at low temperature, which can extend the lifespan of thermally conductive fluid.
● high temperature cooling, refrigeration function, in which direct cooling may be obtained from elevated temperatures (e.g., direct cooling may be obtained from 200 ℃).
● the refrigeration heat exchanger uses a fully brazing plate heat exchanger, which occupies little space and has high heat exchange efficiency.
● the level display function to monitor the level at any time, avoiding fluid deficit.
● multiple protective functions such as high temperature cut-off, acute stop, time delay, electric leakage, over current and over heating, which sufficiently guarantee the safety of use.
● condensation, pre cooling for air cooling, conserve water resources.
Explosion-proof electrical: additional $400.
110V voltage requires an additional $200.
Application:
● temperature control of double-layer and three-layer reactors in chemical, pharmaceutical and biological fields.
● temperature control in material testing.
● temperature control of distillation system.
● temperature change simulation control during the process.
● thermostatic control system.
● temperature control of semiconductor equipment.
● temperature control of thermal test platform.
Model | GDX-10/20 | GDX-20/20 | GDX-30/20 | GDX-50/20 | GDX-100/20 | GDX-200/20 | ||
Technical data | Temperature range | -20~200℃;±1℃ | ||||||
Ambient temperature(℃) | ≤30℃ | |||||||
Ambient humidity | 60% | |||||||
Voltage(V) | 220 | 380(Optional 3P 220V/3P 480V) | ||||||
Phase(P) | 1 | 3 | ||||||
Frequency(Hz) | 50/60 | |||||||
Power(Kw) | 2.8 | 4.5 | 7.7 | 12 | 15 | 23 | ||
Heating capacity(Kw) | 2 | 3 | 4.5 | 6 | 9 | 15 | ||
Cooling capacity(w) | RT | 2200 | 3400 | 7500 | 11500 | 15750 | 31428 | |
0℃ | 1600 | 2100 | 5500 | 8600 | 11000 | 20214 | ||
-20℃ | 1000 | 1800 | 2100 | 3200 | 4300 | 7000 | ||
Temperature sensor | PT100 | |||||||
Protection | Overvoltage, time delay, overcurrent, overheating, leakage, protector | |||||||
Compressor | Type | Closed | ||||||
Brand | Panasonic | Tecumseh/Danfoss/Copeland | ||||||
Power(Kw) | 0.73 | 1.25 | 2.25 | 3.75 | 4.5 | 6 | ||
HP | 1 | 1½ | 3 | 5 | 6 | 8 | ||
Quantity | 1 | 1 | 1 | 1 | 1 | 1 | ||
Refrigerant | R404A | |||||||
Condenser | Type | Air cooling/water cooling | ||||||
Fan type | External rotor axial flow fan | |||||||
Quantity | 1 | 2 | ||||||
Evaporator | Type | Plate heat exchanger | ||||||
Tank volume(L) | 7 | 7 | 10 | 17 | 35 | 50 | ||
External circulation adapter size | G1/2" external interface | G3/4" external interface | G1" external interface | |||||
Circulating pump | Type | Shield pump | Vortex pump | |||||
Brand | Shanghai Jingyi | Aulank | ||||||
Power(w) | 100 | 250 | 370 | 370 | 750 | |||
Current(A) | 1 | 1 | 2.1 | 3.5 | 3.5 | 3.5 | ||
Rated head(m) | 6 | 6 | 8 | 12 | 12 | 12 | ||
Rated flow(L/min) | 25 | 25 | 25 | 35 | 35 | 70 | ||
Appearance dimension | Weight(Kg) | 60 | 90 | 130 | 170 | 220 | 340 | |
Packing weight(Kg) | 80 | 115 | 150 | 220 | 290 | 430 | ||
Chiller size | Length(mm) | 540 | 620 | 710 | 770 | 970 | 1200 | |
Width(mm) | 420 | 540 | 580 | 670 | 800 | 970 | ||
Height(mm) | 800 | 920 | 1090 | 1180 | 1350 | 1580 | ||
Packing size | Length(mm) | 610 | 680 | 770 | 840 | 1040 | 1280 | |
Width(mm) | 510 | 620 | 660 | 760 | 890 | 1050 | ||
Height(mm) | 870 | 1100 | 1220 | 1340 | 1520 | 1760 | ||
*PLC | Control system | Siemens S7-200 smart PLC | ||||||
Programming | 5 programs can be written, each with up to 40 steps | |||||||
Control model | Material temperature and equipment outlet temperature can be switched automatically | |||||||
Protocol | Modbus RTU protocol RS485 interface (optional RS232 Ethernet) | |||||||
Control panel | 7-inch Siemens color touch screen (optional 10 inch) | |||||||
Data export | Support USB flash disk data export, and export temperature data in TXT format | |||||||
Packing list | 2 sets of adapter valves, one roll of raw meal | |||||||
2 stainless steel insulated hoses | ||||||||
Operation instructions | ||||||||
All data are measured in the factory, and users will have errors in the process of use | ||||||||
*PLC for optional PLC part data, it is not applicable if there is no PLC |
型号 | GDX-10/20 | GDX-20/20 | GDX-30/20 | GDX-50/20 | GDX-100/20 | ||
技术参数 | 设计温度范围(℃) | -20~200℃;±1℃ | |||||
环境温度(℃) | ≤30℃ | ||||||
最佳环境湿度 | 60% | ||||||
电压(V) | 220 | 380(可选3P 220V/3P 480V) | |||||
相数(P) | 1 | 3 | |||||
频率(HZ) | 50/60 | ||||||
总功率(Kw) | 2.8 | 4.5 | 7.7 | 12 | 15 | ||
加热功率(Kw) | 2 | 3 | 4.5 | 6 | 9 | ||
制冷量 | RT | 2200 | 3400 | 7500 | 11500 | 15750 | |
(w) | 0℃ | 1600 | 2100 | 5500 | 8600 | 11000 | |
-20℃ | 1000 | 1800 | 2100 | 3200 | 4300 | ||
温度传感器 | PT100 | ||||||
安全保护 | 过压、延时、过流、过热、漏电、保护器 | ||||||
压缩机 | 类型 | 全封闭 | 全封闭 | 全封闭 | 全封闭 | 全封闭 | |
品牌 | 松下 | 泰康/丹佛斯/谷轮 | |||||
功率(Kw) | 0.73 | 1.25 | 2.25 | 3.75 | 4.5 | ||
P数 | 1 | 1½ | 3 | 5 | 6 | ||
数量 | 1 | 1 | 1 | 1 | 1 | ||
制冷剂 | R404 | ||||||
冷凝器 | 类型 | 密闭风冷/可选水冷 | |||||
风机类型 | 轴流外转子 | ||||||
风机数量 | 1 | 2 | |||||
蒸发器 | 类型 | 板式换热 | |||||
液槽容积(L) | 7 | 7 | 10 | 17 | 35 | ||
外循环接口尺寸 | G1/2"外丝 | G3/4"外丝 | |||||
循环泵 | 类型 | 屏蔽泵 | 屏蔽泵 | 旋涡泵 | 旋涡泵 | 旋涡泵 | |
品牌 | 上海精益 | 上海精益 | 奥兰克 | 奥兰克 | 奥兰克 | ||
功率(w) | 100 | 100 | 250 | 370 | 370 | ||
电流(A) | 1 | 1 | 2.1 | 3.5 | 3.5 | ||
扬程(m) | 6 | 6 | 8 | 12 | 12 | ||
额定流量(L/min) | 25 | 25 | 25 | 35 | 35 | ||
外观尺寸 | 重量(Kg) | 60 | 90 | 130 | 170 | 220 | |
装箱重量(Kg) | 80 | 115 | 150 | 220 | 290 | ||
尺寸 | 长(mm) | 540 | 620 | 710 | 770 | 970 | |
宽(mm) | 420 | 540 | 580 | 670 | 800 | ||
高(mm) | 800 | 920 | 1090 | 1180 | 1350 | ||
装箱尺寸 | 长(mm) | 610 | 680 | 770 | 840 | 1040 | |
宽(mm) | 510 | 620 | 660 | 760 | 890 | ||
高(mm) | 870 | 1100 | 1220 | 1340 | 1520 | ||
*PLC | 控制系统 | 西门子S7-200smartPLC | |||||
程序编程 | 可编写5条程序每条可最多达40条步骤 | ||||||
控制模式 | 物料温度与设备出口温度可自行切换 | ||||||
通讯协议 | modbus RTU协议 RS485接口(选配RS232 以太网) | ||||||
操作面板 | 7寸西门子彩色触摸屏(可选10寸) | ||||||
数据导出 | 支持U盘数据导出,可导出温度数据TXT格式 | ||||||
装箱清单 | 适配阀门2组,生料带一卷 | ||||||
不锈钢带保温软管2根 | |||||||
操作使用说明书一份 | |||||||
数据部分为工厂测试数据,实际或许稍微有所偏差 | |||||||
*PLC为选配PLC部分数据,若无PLC不适用 |
Precautions for DOVMXtech-GDX series closed refrigeration heating cycle device:
To ensure the cooling efficiency of the system, in addition to ensuring that the ambient air around the instrument is clean, any dust on the condenser surface must be regularly inspected and cleaned. Please follow the following steps:
① Confirm that the power connector of the equipment has been unplugged.
② Remove the two screws on the lower side of the air intake ventilation net cover of the equipment, then pull the net cover down slightly, and then remove it.
③ Use soft brush or other similar tools to check and clean the dust on the surface of the net cover and condenser.
◆ do not touch the condenser fins with your hands to avoid scratching your hands!
④ After cleaning, install the ventilation net cover and tighten the screws.
We're sorry if we didn't respond in time.
Each equipment will undergo many strict inspections before delivery and transportation to ensure that it is intact. All electrical parts are warranted for one year (except for vacuum pumps and glassware). We have provided double copies for easily damaged items. Please rest assured that the whole machine will be maintained for life. if something breaks, replacement parts will be shipped next day by air.
------