Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
Thermostatic Magnetic Stirring Bath
2 / 4

Thermostatic Magnetic Stirring Bath

Price
$410.00
$0.00
Quantity
SKU: 130CX2055X120BX110D
TYPE

Thermostatic Magnetic Stirring Bath

Features

It can be used as water bath or oil bath. Built-in strong magnetic stirrer in the bath.

Stainless steel 316 heater.

The magnetic stirring system drives the stirrer to rotate synchronistically, so that the solution in the bath can be heated and stirred evenly.

DC brushless motor ensures stable performance and continuous working.

High temperature magnet can continuously work at 300℃ without losing magnetism.

PID temperature controller ensures accurate temperature control.

Key setting and digital display make it easy to operate.

Equipped with two sensors make bath temperature and container temperature display alternately.

there are two sensors in hwcl-3 and hwcl-5, and the temperature in the bath and the temperature in the reaction vessel can be displayed.

Note: hwcl-3 and hwcl-5 are built-in sensors. If it is necessary to test the temperature in the reaction vessel, insert the external sensor and put it into the reaction vessel; Hwcl-1 is an external sensor, which can measure temperature when put into the reaction vessel.

 

  

Magnetic stirrer DOVMXtech HWCL-1 split collector constant temperature magnetic stirring bath

Note: hwcl-1 has no secondary mixing, only external sensor, no cover!

(split type live pot, which can be used as flat magnetic stirring after the pot is removed)

When the external sensor is connected, it must be ensured that the sensor probe is immersed in the bath liquid or reaction material in the tank, so as not to be heated all the time and cause danger.

型号

DOVMXtech HWCL-1

使用温度范围(℃)

室温+5200

温度稳定性()

±1

温度设定显示

按键输入,数显显示

转速设定

旋钮设定

转速(rpm)

02000

浴槽尺寸(mm

Ф140×108

浴槽容积(L

1

加热功率(W)

300

最大可放置烧瓶(ml)

500

电源(V/Hz

1~,110V60Hz220V-240V50/60Hz

外形尺寸(mm)

190W×200D×190H

净重(Kg)

3

 

 

DOVMXtech HWCL-3 heat collecting magnetic stirrer strong magnetic stirrer with two-stage stirrer

Note: hwcl-3 and hwcl-5 are built-in sensors. If it is necessary to test the temperature in the reaction vessel, insert the external sensor and put it into the reaction vessel; Hwcl-1 is an external sensor, which can measure temperature when put into the reaction vessel.

型号

DOVMXtech HWCL-3

使用温度范围(℃)

室温+5200

温度稳定性()

±1

温度设定显示

按键输入,数显显示

转速设定

旋钮设定

转速(rpm)

02000

浴槽尺寸(mm

Ф220×110

浴槽容积(L

4

加热功率(W)

500

最大可放置烧瓶(ml)

3000

电源(V/Hz

1~,110V60Hz220V50/60Hz

外形尺寸(mm)

260W×280D×230H

净重(Kg)

5

 

DOVMXtech HWCL-3

Packing list of heat collecting constant temperature magnetic stirring reaction bath

序号

名 称

单位

数量

备注

  1. 1.     

主 机

1

 

  1. 2.     

使用说明书

1

 

  1. 3.     

保修卡

1

 

  1. 4.     

保险管

1

15A

  1. 5.     

搅拌立杆

1

L=230㎜

  1. 6.     

搅拌子

1

B835

  1. 7.     

水浴锅盖

1

 

  1. 8.     

搅拌盘

1

 

  1. 9.     

传感器

1

 

  1. 10. 

百叶盖

4

 

  1. 11. 

二级搅拌

1

 

 

 

DOVMXtech HWCL-3S deep pot heat collecting constant temperature magnetic stirring bath Main technical parameters

型号

DOVMXtech HWCL-3S

使用温度范围(℃)

水浴

室温+5~95

油浴

室温+5~200

温度稳定性(℃)

±1

温度设定及显示方式

按键输入,LED显示

转速设定方式

旋钮设定

转速范围(rpm)

0~2000

加热器额定功率(W)

500

保护功能

过电流、接地故障及超温保护

电源(V/Hz)

110V~,60Hz或220V—240V~,50/60Hz

浴槽尺寸(mm)

φ220×160

浴槽容积(L)

6

可放置的最大烧瓶(ml)

3000

外形尺寸(mm)

260W×300D×490H

净重(Kg)

5.5

 

 

DOVMXtech HWCL-5 Heat collecting constant temperature magnetic stirring bath Main technical parameters

型号

DOVMXtech HWCL-5

使用温度范围(℃)

室温+5200

温度稳定性()

±1

温度设定显示

按键输入,数显显示

转速设定

旋钮设定

转速(rpm)

02000

浴槽尺寸(mm

Ф254×130

浴槽容积(L

6.5

加热功率(W)

1050

最大可放置烧瓶(ml)

5000

电源(V/Hz

1~,110V60Hz220V-240V50/60Hz

外形尺寸(mm)

260W×280D×260H

净重(Kg)

6

 

 

remarks:

Hwcl-1 has only external sensors, and the sensor probe must be immersed in bath liquid or reaction material liquid.

Hwcl-3 and hwcl-5 have two functions: internal sensor and external sensor. Hwcl-3 and hwcl-5 are built-in sensors. If it is necessary to measure the temperature of materials in the reaction vessel, insert the external sensor into the sensor interface and immerse the sensor probe into the material liquid of the reaction vessel; If the temperature in the reaction vessel is not measured, please unplug the external sensor and enable the internal sensor to operate. When the internal sensor and the external sensor are switched, they must be powered off and restarted to take effect. If the built-in sensor fails, connect the external sensor and immerse the sensor probe into the bath solution in the bath.

How to use hwcl series products:

1. Fix the reaction vessel firmly, and then add appropriate bath solution into the bath according to the temperature.

2. If water bath or oil bath is used for mixing, appropriate amount of water or oil shall be added according to the size and height of the container (Note: water or oil cannot be filled too full to prevent overflow, damage to the machine and danger); The temperature measurement of the liquid level is the best at 2 / 3 of the bath.

matters needing attention

This product cannot be used in flammable and explosive places. Dry burning is prohibited.

When using this product, the bath liquid has a high temperature. Please be careful of scalding.

Please cut off the power supply when not doing the experiment.

Unattended work is prohibited to avoid accidents.

Place the container in the center of the tank.

If the switch indicator is not on after power on or the temperature display window is not displayed after the switch is turned on, please check the fuse tube.

Unplug the external sensor when it is not used.

When the external sensor is connected, it must be ensured that the sensor probe is immersed in the bath liquid or reaction material in the tank, so as not to be heated all the time and cause danger.

Note:

hwcl-1 has only external sensors, while hwcl-3 and hwcl-5 have two functions: internal sensors and external sensors.

Before use, please confirm that the secondary mixing (equipped with hwcl-3 and hwcl-5) is placed in the correct direction to ensure the normal operation of the machine.

Usage of heat collecting constant temperature magnetic stirring bath:

1. Fix the reaction vessel firmly, and then add appropriate bath solution into the bath according to the temperature.

2. If water bath or oil bath is used for mixing, appropriate amount of water or oil shall be added according to the size and height of the container (Note: water or oil cannot be filled too full to prevent overflow, damage to the machine and danger); The liquid level is measured at 2 / 3 of the bath.

3. Turn on the power supply, turn on the heating switch, and display the measured temperature when entering the operating state. After setting the temperature, the machine will enter the normal working state.

4. Rotate the switch potentiometer as required, turn on the mixing function and slowly adjust the speed.

5. Temperature setting: click the set key to display the SP and the set value cyclically, and modify the set value by increasing "▲" and decreasing "▼". Click set to confirm and exit the setting state.

6. After long pressing the "▼" key for 5S, the heating lamp flashes and the alarm lamp goes out, and the instrument enters the self-tuning state. After the self-tuning, a set of PID parameters that can make the equipment temperature control effect state are obtained. After that, the instrument performs temperature control according to the new PID parameter value. (after using or replacing the medium for the first time, please self adjust to make the temperature control more accurate.)

7. Hwcl-3 and hwcl-5 are built-in sensors. If it is necessary to measure the temperature of materials in the reaction vessel, insert the external sensor into the sensor interface and immerse the sensor probe into the material liquid of the reaction vessel; If the temperature in the reaction vessel is not measured, please unplug the external sensor and enable the internal sensor to operate. When the internal sensor and the external sensor are switched, they must be powered off and restarted to take effect. If the built-in sensor fails, connect the external sensor and immerse the sensor probe into the bath solution in the bath. Hwcl-1 is an external sensor, and the sensor probe must be immersed in bath liquid or reaction material liquid.

 

常见故障分析及排除                                                                  

序号

现象

故障判断

解决方法

1.

整机无电

电源无电

检查电源

保险管熔断

更换保险管

2.

无温度显示

电源开关没打开

打开电源开关

显示板排线脱落

插好连接排线

线路板上被溅水/油

吹干后开机

3.

显示“SEr”

外置传感器掉落

检查外置传感器,并重启电源

4

显示“ER1”

外置传感器故障

断电重启,如仍有故障,更换传感器

5

显示“ER2”

内置传感器故障

6

显示“bAL”

测量温度过高(大于绝报警值)

断电重启

7

不搅拌

二级搅拌移位,搅拌子跳动

底座或烧杯不平稳

8

加热工作正常

搅拌控制失常

电位器坏

更换电位器

开关电源无输出DC24V

更换开关电源

旋转控制器坏

更换控制器

电机电源线脱落

插好连接线

电机损坏

更换电机

  

Tips: This product is quoted according to the actual needs of customers, please contact customer service for ordering. 
1.Description of supplier
Real manufacturers, from the processing of glass to the production of a complete set of equipment, are welcome to visit and guide. 
2.About size and Packaging
Waterproof film winding, filled with foam cotton, packed in wooden cases.
The packaging size of each model is different, please contact customer service for details. 
3.About customer service
Online customer service working hours: 8:00 am to 6:00 pm Beijing time.
We're sorry if we didn't respond in time. 
4.About after sales
Each equipment will undergo many strict inspections before delivery and transportation to ensure that it is intact. All electrical parts are warranted for one year (except for vacuum pumps and glassware). We have provided double copies for easily damaged items. Please rest assured that the whole machine will be maintained for life. if something breaks, replacement parts will be shipped next day by air.
5.About delivery
We can provide door-to-door transportation services, worry-free delivery, including customs clearance. The cost is very reasonable. As long as you give us an address, we can deliver the equipment to your door. You don't need to worry about international transportation.
For more types and detailed product configuration, or customization as required, please contact us by email: info@dovmxtech.com


------